[Acoustic] User Defined Property Set

1 min. readlast update: 09.24.2024

Attached at the bottom is a link to Naviate Bimfire's User defined property set file which can be used and manipulated for each project.

 

It's possible to define which Revit parameter should be exported with the IFC, and which tab in the IFC the values should be placed. It is also possible to rename parameters.

 

The User defined property set file is text file, that can be edited by any user.

Every row with a # will not be read by Revit, so it's just comments within the file.

 

  1. The tab name in the IFC.
  2. Instance or Type parameters, Naviate Bimfire users will always use Instance (I) for requirements.
  3. Which IFC classes (objects) should be effected, IfcProduct means "everything". Could have been "IfcDoor, IfcWall" etc.
  4. Parameter in Revit to export.
  5. Parameter typ to export, such as Area, Label (text parameter), and Length.
  6. The parameter name in the IFC export. In this scenario, AcousticReq_AcousticRatingWall should be named "Wall Requirement". Change to what is required in the project. Talk to the BIM Coordinator.

 

In IFC Export Setup, add the NaviateBFAcoustic_Property_Set file in Export user-defined property sets

 

 

In Revit

The IFC

 

Was this article helpful?